Systematic heating
The module
Technology
Connecting ball valves DN 20 (3/4“) internal thread
Plastic cover H=600 mm, W=400 mm, D=190 mm
Primary side | Secundary side | ||||||
---|---|---|---|---|---|---|---|
Flow/Return °C | V [m³/h] | Pressure loss | Heating system | Flow/Return °C | V [m³/h] | Residual head [mWs] | Qmax [kW] |
75/43 | 0,67 | 1,5 | Radiators with or without buffer tank | 65/40 | 0,86 | 4,8 | 25 |
75/33 | 0,8 | 1,8 | Underfloor heating with mixing valve and buffer tank | 65/28 | 0,9 | 4,6 | 38 |
75/33 | 0,3 | 0,9 | Underfloor heating controlled directly by the heat exchanger | 35/28 | 1,6 | 1,7 | 13 |
The module is delivered as a whole unit already pre-assembled on a mounting plate and contains:
Primary side:
Secundary side:
Control system already integrated for the integrated mixing circuit and the hot water tank loading or for the buffer charging.
For additional mixing circuits, either the mixing circuit module or a heating control for 2 further
mixing circuits is required.
The components inside the module are already pre-wired.
A touchscreen control panel with Ethernet interface is included in the scope of delivery.
Control system contains 5 freely available sensor inputs and an MBUS circuit board for visualization of heat meters with suitable interface.