Less ash, more comfort
Less ash, more comfort

Thanks to optimised combustion processes, very little ash is produced. This is further compressed tightly in the ash container, so that the container needs to be emptied less frequently. When the time comes, the boiler automatically sends a reminder by email.

Maximum fire safety
Maximum safety against backdraft

The single-chamber rotary valve prevents against backdraft and operates in an energy-saving and efficient way. Thanks to the automatic rotary valve stop and shared drive with the stoker screw, it does not require its own motor. A hardened blade ensures that oversized fuel particles are reliably cut off.

Simple to control – conveniently manage fire control, pellet feed, hot water and heating circuits via display or meinETA .
Simple regulation

Whether it's fire control, pellet conveying, buffer management, hot water preparation, weather-compensated heating circuit control with a weekly programme for two circuits or the connected solar system - all of this can be easily controlled via the display on the boiler or via the internet remote control meinETA. 

Cleanliness yields the highest efficiency
Cleanliness yields the highest efficiency

The combustion chamber has a multi-layered structure. Together with the water-cooled grate side rails, the entire boiler construction ensures a long service life, low radiation losses and therefore high efficiency.

Automatic removal of ash
Automatic removal of ash

The removal of the ash can be individually adapted to the structural conditions and the type of transport.

Optional combustion chamber camera in the boiler
Combustion chamber camera

The optional combustion chamber camera actively intervenes in the control system. This further optimises combustion when fuel quality fluctuates.

Separately controlled flue gas recirculation ensures a stable temperature range in the combustion chamber and thus protects the boiler
Separately regulated flue gas recirculation

It ensures a stable temperature range in the combustion chamber and thus protects the boiler. There is no slag on the grate, even with different fuels.

External electrostatic precipitator to further reduce emissions
External electrostatic precipitator

The ETA EEP enables emissions to be reduced further. The dedusting, as with the boiler, is done automatically into an ash bin.

ETA HACK VR 
A look inside the boiler 

When selecting a new heating boiler, you are making a decision that can have an effect on your daily life for many years. You determine how safe you can feel and how much you have to worry about maintenance or cleaning. Take a look inside your future wood chip boiler in advance. 

Extremely energy-efficient draught fan

It ensure underpressure and thus safety in the boiler – and is especially energy-saving: The ideal speed required for the underpressure is passed on to the motor via a frequency converter.

Separately regulated flue gas recirculation

It ensures a stable temperature range in the combustion chamber and thus protects the boiler. There is no slag on the grate, even with different fuels.

Primary and secondary air

The primary and secondary air supply is pre-heated and thus cools the boiler's outer layer. This minimises radiation losses. The efficiency of the whole system is increased. Starting at 333 kW, a motor controlled by a frequency converter ensures optimal speed.

Single chamber rotary valve

It reliably prevents backdraft and thus ensures the highest safety. The large chamber is only filled at standstill, thanks to the automatic rotary valve stop. So the rotary valve works particularly efficiently and energy-saving and can be driven by just one motor together with the stoker screw. A hardened blade with counter-blade reliably cuts off oversized fuel parts. So nothing gets jammed.

Stoker screw

Thanks to a special trough geometry and the progressive stoker screw, it operates with low-wear and largely without disruptions.

Lambda and combustion chamber temperature regulation

By adjusting the oxygen supply to the respective fuel quality, the boiler achieves maximum efficiency with the lowest emissions. The temperature of the combustion chamber is controlled as needed by the flue gas recirculation flap.

Combustion chamber with moving grate

The combustion chamber with its multi-layered, high temperature-resistant construction is made for the highest loads. The firebed is constantly stoked. The combustion chamber area on the sides is provided with extra protection by water-cooled side rails. This ensures the long lifetime for the boiler. De-ashing takes place automatically, whereby a common drive for grate and ash rake is sufficient.

Touch controller with microprocessors

The whole touch control system of the heating system is located directly on the boiler and is already pre-wired. Four different mounting positions are possible. The menu guidance works via touchscreen with clear images. Visualisations of the working processes of the heating system as well as remote control are possible via the internet with meinETA, including email messaging system, partner network and software updates via USB connection.

Vertical pipe heat exchanger

Automatic cleaning ensures constantly high efficiency. An integrated multi-cyclone cuts coarse dust through rotation, thus preventing dangerous sparks and at the same time lowering the dust emissions. It is already integrated into the system and thus needs less space than an external device and also generates no extra costs. The flue tube connection is designed to pivot.

Automatic, complete de-ashing

The grate and cyclone ash are collected and transported away via a high-quality shaftless inclined screw with temperature monitoring, for which coarse foreign bodies in the ash are no problem either. Further disposal takes place via a spherical transition on which the de-ashing variants can be connected. 

Electrostatic precipitator

Minimal emissions through clever use of natural phenomena

The percipitator in the boiler ensures even cleaner and more environmentally friendly heating with wood. With an impressive capture efficiency of 80–85%, emissions are reduced to a barely measurable level. Retrofitting is also possible without any problems.

meinETA 
Simple and controllable from anywhere

ETAtouch: the touchscreen on the boiler
The days of confusingly arranged buttons and controls are over, because with the ETA touchscreen you can adjust all settings conveniently and easily. The icons are self-explanatory. Whether you want to make it warmer overall or cooler, change the timer for night-time reduction or you want to switch to reduced-temperature mode during your vacation - you just tap on the right symbol intuitively - no need for operating manuals!

Free platform

If your boiler is online, you can control the heating free of charge via mobile phone, tablet or PC – anytime, anywhere.

Quick help

Enable access and resolve issues by phone – you decide whether to share access.

Quality from Austria

ETA stands for quality: patented systems from Austria, manufactured in the Hausruck region.

ETA
Energy Container

Outdoor heating unit for retrofitting

You want to switch to a biomass heating system, but don't have a suitable boiler room or store? ETA offers compact container solutions made of reinforced concrete – tailor-made and compliant with fire protection regulations. Whether it's a single-family home, residential complex or commercial property: We plan the size, features and boiler output exactly according to your needs. A foundation plan will be provided upon order and must be implemented on site by a master builder.

Tailor-made solutions

Boiler output, size and features are precisely tailored to your needs.

Space-saving & efficient

No additional boiler room is needed – the compact unit is quickly ready for use.

Ideas for your boiler room

A new heating system improves both your comfort as well as the energy efficiency of your home. With our HACK VR wood chip boilers, you get a sustainable, tailor-made solution. In our references, you will find various ideas for boiler rooms that will help you find the optimal solution for your needs.

Search for reference projects

District heating & cooling
ETA HACK VR 250 kW
Stöckl
84405 Dorfen
Germany
Commercial units (offices, hotels, public buildings) Building)
ETA HACK VR 2 x 500 kW
BREZA COMMERCE, d.o.o.
4224 Gorenja
Slovenia
District heating & cooling
ETA HACK VR 350 + 500 kW
Haab & Bossert GmbH
8820 Wädenswil
Switzerland
Commercial units (offices, hotels, public buildings) Building)
ETA HACK VR 2 x 350 kW
Leipfinger Energie u. Hackschnitzel
84427 St. Wolfgang
Germany
District heating & cooling
ETA HACK VR 3 x 463 kW
Heidemann Holzenergie GbR
86476 Neuburg a. d. Kammel
Germany
District heating & cooling
ETA HACK VR 350 kW
Stadtwerke Schwäbisch Hall GmbH
74523 Schwäbisch Hall
Germany
District heating & cooling
ETA HACK VR, ETA eHACK Total: 700 kW
Gerd Seebach
74532 Ilshofen
Germany
District heating & cooling
ETA HACK VR 1 x 350 kW, 1 x 500 kW
Christoph Fendt
86473 Muttershofe
Germany
Commercial units (offices, hotels, public buildings) Building)
ETA HACK VR 2 x 463 kW (cascade)
Bio Energie Tripkau GmbH
19273 Tripkau
Germany

Are you looking to find the perfect heating solution for your home?